Esta página reúne las fuentes que citan los artículos de Climatización Empresas. Solo publicamos cifras que hemos podido comprobar en su documento original o en su resumen oficial; las que circulan en el sector sin fuente localizable no se usan. Última verificación: 20 de octubre de 2026.
Mantenimiento y eficiencia
- U.S. Department of Energy, FEMP. Operations & Maintenance Best Practices Guide, Release 3.0, 2010. Ahorro del 12 % al 18 % del preventivo frente al correctivo y del 8 % al 12 % del predictivo frente al preventivo.
- Mills, E. Lawrence Berkeley National Laboratory. Building Commissioning: A Golden Opportunity for Reducing Energy Costs and Greenhouse Gas Emissions, 2009. 643 edificios de Estados Unidos; ahorro mediano del 16 % y retorno de 1,1 años en edificios existentes.
- U.S. Department of Energy. Maintaining Your Air Conditioner (copia archivada de enero de 2024). Un filtro limpio reduce entre un 5 % y un 15 % el consumo.
- Downey, T. y Proctor, J. What Can 13,000 Air Conditioners Tell Us? ACEEE, 2002.
- Siegel, J., Walker, I. y Sherman, M. Dirty Air Conditioners: Energy Implications of Coil Fouling. LBNL, ACEEE, 2002.
- ASHRAE y ACCA. ANSI/ASHRAE/ACCA Standard 180-2018.
Calidad del aire, ductos y salud
- U.S. EPA. The Inside Story: A Guide to Indoor Air Quality.
- U.S. EPA. Should You Have the Air Ducts in Your Home Cleaned?
- Allen, J. G. et al. Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and VOC Exposures in Office Workers. Environmental Health Perspectives 124(6), 2016.
- Mendell, M. J. et al. Risk factors in HVAC systems for occupant symptoms in US office buildings: the US EPA BASE study. Indoor Air 18(4), 2008.
- Fisk, W. J. et al. Quantitative relationship of sick building syndrome symptoms with ventilation rates. Indoor Air 19(2), 2009.
- Seppänen, O. y Fisk, W. J. Association of ventilation system type with SBS symptoms in office workers. Indoor Air 12(2), 2002.
- Wargocki, P. et al. Ventilation and health in non-industrial indoor environments: EUROVEN consensus. Indoor Air 12(2), 2002.
- Bourbeau, J. et al. Prevalence of SBS symptoms before and after exposure to a building with an improved ventilation system. Occupational and Environmental Medicine, 1996, y seguimiento de 1997.
- Zuraimi, M. S. Is ventilation duct cleaning useful? A review of the scientific evidence. Indoor Air 20(6), 2010.
- Ahmad, I., Tansel, B. y Mitrani, J. D. Effectiveness of HVAC Duct Cleaning Procedures in Improving Indoor Air Quality. Environmental Monitoring and Assessment 72(3), 2001.
- Bakker, A. et al. Bacterial and fungal ecology on air conditioning cooling coils is influenced by climate and building factors. Indoor Air, 2019.
- Shiraishi, Y. et al. A Method to Evaluate and Eliminate Fungal Contamination in Household Air Conditioners, 2023, y Fungal Load and Composition in Residential Air Conditioners Recontaminated 1 Year After Cleaning, 2026. Indoor Air.
- Okada, N. et al. Moldy odor from air conditioners in the residences of Japanese participants with and without asthma. Indoor Air 32(9), 2022.
- Zhai, Z. et al. Full-Scale Laboratory Test on Energy Dependence on Pressure Drops in HVAC Systems. Procedia Engineering 205, 2017.
Refrigeración comercial
- Key implications on food storage in cold chain by energy management perspectives. Frontiers in Sustainable Food Systems, 2023.
- Morozyuk, L. et al. Experimental study and analysis of an air-cooled condenser with the fouling on the heat exchange surface for small-scale commercial refrigeration systems. International Journal of Air-Conditioning and Refrigeration, 2023.
Cocinas comerciales
- Campbell, R. National Fire Protection Association. Structure Fires in Eating and Drinking Establishments, febrero de 2017 (copia archivada).
- National Fire Protection Association. NFPA 96: Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations.
Hoteles, edificios y energía
- Agencia Internacional de la Energía. The Future of Cooling, 2018.
- Peña, D. Altas temperaturas disparan la demanda eléctrica, advierte la Secretaría de Energía. La Estrella de Panamá, 26 de mayo de 2026.
- U.S. CDC. About Legionnaires’ Disease y Controlling Legionella in Cooling Towers.
- ASHRAE. ANSI/ASHRAE Standard 188-2021.
Cifras que no usamos
Algunas cifras circulan en webs del sector atribuidas a organismos que no las publicaron, o se citan fuera de contexto. Estas son las que hemos descartado por no poder comprobarlas en su fuente:
- Porcentajes de ahorro con decimales, del tipo «45,37 % de ahorro», sin estudio que los respalde.
- Un «30 % más de consumo del compresor» por condensadores sucios atribuido al Departamento de Energía de Estados Unidos.
- Un ahorro del «41 % al 60 %» por limpiar el sistema presentado como consumo total, cuando el estudio original mide solo la energía del ventilador.
- Un «270 % más de consumo» por polvo en ductos, que procede de una simulación sin validación de campo.
Si detecta un error en alguna cifra, revisaremos la fuente y corregiremos el artículo.